Dual-energy CT: Is it what the doctor ordered for the cost-conscious community hospital?

A hospital seeking to replace CT technology that does not meet the XR-29 standard has a wide range of slice counts and capabilities to consider, all the way up to state-of-the-art—but pricey—dual energy CT (DECT).

For hospitals in the community-provider category, however, dual-energy CT capability likely represents overkill when it comes to meeting the typical caseload of a radiology department in the  community hospital setting. Focused on right-sizing their technology due to cost-effectiveness concerns, many hospital radiology administrators are foregoing DECT purchases.

So concludes Greg Freiherr, a journalist and consultant who has covered and closely tracked the field of medical imaging technology for 32 years. Freiherr fleshes out the details informing his conclusion in a white paper commissioned by Hitachi Medical Systems to best understand the imaging needs of today’s community hospitals.

He identifies two factors behind community hospital reluctance to adopt DECT. One, the shift in U.S. healthcare from volume-based reimbursement to a thriftier value-based model proceeds apace. And two, mid-tier 64- and 128-slice CTs continue to prove adequate in handling not only a vast swath of routine radiological exams but also most advanced cardiological and neuroradiological ones.

Freiherr’s methodology included examining peer-reviewed journal articles for clinical data and analyses about the use and adoption of spectral and dual-energy CT, along with interviewing experts and radiology administrators, and correlating their experiences with information obtained online and in print.

He spoke with imagingBiz about the project and the observations he made while working on it.

“Dual-energy CT is probably the most advanced technology that we have in computed tomography,” Freiherr says. “But you are not going to find a lot of benefits in the business returns on the investment, especially for community hospitals. You truly are looking at purely clinical benefits in very selective areas.”

What is DECT and why is it here?

DECT technology leverages the propensity of anatomic structures and elements within the body to absorb and attenuate x-rays differently, depending on the level of energy sent into them. The technique allows a diagnostic imager to obtain two sets of data in every CT slice—one at lower energy, such as 60 or 80 keV, the other at higher energy, such as 120 or 140 keV.

Freiherr’s paper notes that, while this dual capability is unique to DECT, the latest generation of 64- and 128-slice CTs also can be set to scan at low energy, typically 80 keV.

“In certain circumstances, you can see more, ironically, with low power then you can at high power,” Freiherr explains. “With DECT you can finesse the imaging so that you’re able to look at certain disease conditions from two views, with or without contrast.”

DECT has been on the market in the U.S. since 2006. The first iteration relied on the use of two x-ray tubes, Freiherr says. Soon others systems appeared using a single x-ray tube that switched between two energies and  CT detectors that could sort out energies contained in a multi-energy beam.

The technology is well suited to fine-tuning diagnosis and guiding treatment for conditions such as gout and kidney stones. The latter problem is an especially good example, Freiherr points out, because the chemistry of most but not all kidney stones involves calcium, which absorbs the energy at a specific level. “The ability to distinguish between types of stone can be handy,” he says, “because the therapy for one kind of stone is completely different than the therapy for the other kind.”

Freiherr noted, however, that less expensive—although more time consuming—means exist for distinguishing between these stones.

At the same time, DECT has some attractive dose-reduction aspects. Because it acquires data sets at two energies, a patient may be administered contrast and scanned just one time. The contrast can be virtually subtracted by algorithm, providing the diagnostician with two exams, contrast and non-contrast, out of that single scan. “In a contrast-enhanced CT angiogram, for example, you cut your radiation exposure to the patient by 50% just like that,” says Freiherr, who noted that lower patient doses of radiation also can be achieved using conventional CT.

Dollars and sense 

The price of CT scanners has fallen dramatically in recent years just as their diagnostic power has risen.  Comparing price points, Freiherr’s white paper notes that 16-slice scanners were once considered super-premium CTs yet are now entry-level products. “Even more advanced scanners—64- and 128-slice CTs whose predecessors propelled radiology 10 years ago to the fringes of cardiological practice— are now mid-tier,” he writes. “The operation of these systems has been automated and their dose to patients reduced, as their prices have fallen dramatically.”

Industry data indicates that today’s 16-slice scanners average $402,000. That’s well under half the $1 million-plus price tag these scanners commanded when they were introduced in 1998, Freiherr reports, adding that the more powerful 64- and 80-slice scanners average $549,000.  

“And these have all gotten even better,” he told imagingBiz. “Because they are now low-dose, they are very capable of doing virtually all radiological applications. A 16-slice can handle just about everything—trauma, orthopedics, cancer. When you get to 64-slice, you are able to do advanced cardiological applications. And you are still well under $1 million.”

Meanwhile, as the white paper states, premium scanners capable of DECT cost, on average, $1.29 million and sometimes much more.

“And of course your total costs—acquisition, implementation, training, service, PACS-related costs—are going to be higher with DECT,” Freiherr says. “A Ferrari doesn’t just cost more than a Chevy out of pocket. The Ferrari costs more to drive and maintain too. It’s just that way.”

Which, in this era of value over volume, brings the discussion to the question at hand: What CT capabilities do community hospitals need today?

What price, prestige? 

Freiherr says community hospitals’ CT needs revolve around their focus on the “bread and butter” procedures—emergency, inpatient, outpatient, screening—that, in essence, define what a community hospital is and does.

His paper provides several illustrative case studies of community hospitals and their respective CT workloads. At 140-bed, St. Elizabeth East Hospital in Lafayette, Ind., with two CT scanners, for example, the ED drives about 45% of its total CT usage. The other 55% of the facility’s scans are occasioned by conditions involving orthopedics, oncology and family practice, along with such procedures as CT-guided biopsies and drainages.

Here as elsewhere, “if something shows up that a community hospital can’t diagnose, they have the option to send the patient to a regional or academic center,” Freiherr says.

The paper notes that, across all hospital types, DECT adoption has been considerably slower than with previous advances in CT technology. Asked what he discovered about why more hospitals are not buying into the technology, Freiherr offers the following observation.

“You find DECT mostly in academic centers and large hospitals that have some specific need for it, maybe due to patient demographics,” he says. “Some want to have the technological firepower it can take to attract the best and the brightest research and clinical talent. Others might like it for marketing. It can provide a way to have patients identify the name of the hospital or health system with the latest and greatest technologies.”

Patient-centered acquisition decisions 

For most hospitals dealing with the move to value-driven medicine, the choice of CT tends to be made on the basis of which one provides the most value to their patients, Freiherr stresses, and is within budget.

Community hospitals may be especially susceptible to financial pressures because their revenues are not as broadly based. “They don’t have NIH funding for research, and they don’t have philanthropists who are going to give them $70 million to work on the disease that took their loved one,” he says. “They have to ask, ‘What are we getting reimbursed for? How are we going to get reimbursed? And how does this relate to the patient mix we serve?’”

Freiherr concludes: “If it comes down to making a good business decision, and 90% or 95% of your patients can be taken care of with a less expensive CT scanner, you definitely want to go with the less expensive scanner.”

Read more: Do community hospitals need dual-energy CT?

Dave Pearson

Dave P. has worked in journalism, marketing and public relations for more than 30 years, frequently concentrating on hospitals, healthcare technology and Catholic communications. He has also specialized in fundraising communications, ghostwriting for CEOs of local, national and global charities, nonprofits and foundations.

Around the web

The patient, who was being cared for in the ICU, was not accompanied or monitored by nursing staff during his exam, despite being sedated.

The nuclear imaging isotope shortage of molybdenum-99 may be over now that the sidelined reactor is restarting. ASNC's president says PET and new SPECT technologies helped cardiac imaging labs better weather the storm.